OML _ Laboratory order for multiple orders related to a single specimen
ER7
Note that the overriding of IHE Laboratory Profile constraints is only allowed in
national extensions to this framework
2.15.9.1
2.15.9.2
2.15.9.7
Retained for backward compatibility only
2.15.9.8
Its content is defined within each transaction-specific section of this document
2.15.9.9
This field contains a number or other identifier that uniquely identifies the
message. Each message should be given a unique identifier by the sending system. The
receiving system will echo this ID back to the ending system in the Message Acknowledgment
segment (MSA).
2.15.8.2
2.15.9.11
2.15.9.12
2.15.9.13
2.15.4.1
2.15.9.15
2.15.9.16
2.15.9.17
ASCII: The printable 7-bit ASCII character set. 8859/1: The printable characters
from the ISO 8859/1 Character set used by Western Europe. This character set can still be
used, but 8859/15 should be used by preference. This character set is the
forward-compatible version of 8859/1 and includes new characters such as the Euro currency
symbol. ISO IR87: Code for the Japanese Graphic Character set for information interchange
(JIS X 0208-1990).
2.15.9.18
2.15.9.19
2.15.9.20
Note that the overriding of IHE Laboratory Profile constraints is only allowed in
national extensions to this framework
2.15.9.21
2.15.12.1
2.15.12.2
2.15.12.3
2.15.12.4
2.15.12.5
2.15.12.6
Retained for backward compatibility only
2.15.10.1
2.15.10.2
This field contains the text of the comment. This text may be formatted. In
order to delete an existing comment, the field shall contain empty quotation
marks: " " . Comment text of identical type and source shall be included in the
same occurrence of an NTE segment, and not be split over multiple segments.
2.15.10.3
The IHE Laboratory Technical Framework populates this field with one of the
values in table IHE0364
2.15.10.4
The specific usage of the fields,with usage " Optional" in the table PID, is
explained in the national extensions.
3.4.2.1
3.4.2.2
*
3.4.2.3
3.4.2.4
3.4.2.5
Retained for backward compatibility only
Retained for backward compatibility only
3.4.2.6
Retained for backward compatibility only
Retained for backward compatibility only
If the exact date of birth is not known, the second component of this field can
be used to describe the degree of precision of the information entered in the first
component.
3.4.2.7
Retained for backward compatibility only
3.4.2.8
3.4.2.9
Retained for backward compatibility only
Retained for backward compatibility only
3.4.2.10
3.4.2.11
deprecated as of v2.5
Retained for backward compatibility only
Retained for backward compatibility only
3.4.2.12
3.4.2.13
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
3.4.2.14
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
3.4.2.15
3.4.2.16
3.4.2.17
the Patient Account Number is not used in some countries: in the US, it must be
valued and the PV1-19 visit number is required when PID-18 identifies an account that
spans more than one Encounter or Visit. In France, PID-18 may be used when a patient may
have multiple visits (each visit having independent transfer and discharge) but where
all the visit need to be linked under one case/episode number.
3.4.2.18
3.4.2.19
3.4.2.20
3.4.2.21
3.4.2.22
3.4.2.23
3.4.2.24
3.4.2.25
3.4.2.26
3.4.2.27
3.4.2.28
3.4.2.29
Retained for backward compatibility only
3.4.2.30
3.4.2.31
3.4.2.32
3.4.2.33
Retained for backward compatibility only
3.4.2.35
3.4.2.36
3.4.2.37
3.4.2.38
3.4.2.39
3.4.5.17
3.4.5.21
3.4.10.3
3.4.10.4
Retained for backward compatibility only
Retained for backward compatibility only
3.4.5.24
3.4.5.36
3.4.4.43
3.4.4.44
3.4.10.9
3.4.10.10
3.4.5.22
3.4.5.23
3.4.10.13
3.4.10.14
3.4.10.15
3.4.10.16
3.4.10.17
3.4.10.18
3.4.10.19
3.4.10.20
3.4.10.21
2.15.10.1
2.15.10.2
This field contains the text of the comment. This text may be
formatted. In order to delete an existing comment, the field shall contain
empty quotation marks: " " . Comment text of identical type and source shall
be included in the same occurrence of an NTE segment, and not be split over
multiple segments.
2.15.10.3
The IHE Laboratory Technical Framework populates this field with one of
the values in table IHE0364
2.15.10.4
3.4.5.1
3.4.5.2
Retained for backward compatibility only
Retained for backward compatibility only
3.4.5.3
3.4.5.4
deprecated as of v2.5
Retained for backward compatibility only
Retained for backward compatibility only
3.4.5.5
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
3.4.5.6
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
3.4.5.7
3.4.5.8
3.4.5.9
3.4.5.10
3.4.5.11
3.4.5.12
3.4.5.13
3.4.2.16
3.4.2.8
3.4.2.7
Retained for backward compatibility only
3.4.5.17
3.4.3.15
3.4.2.26
3.4.2.15
3.4.5.21
3.4.5.22
3.4.5.23
3.4.5.24
3.4.2.17
3.4.2.6
Retained for backward compatibility only
Retained for backward compatibility only
3.4.2.28
3.4.2.22
3.4.5.29
3.4.5.30
Retained for backward compatibility only
Retained for backward compatibility only
3.4.5.31
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
3.4.5.32
deprecated as of v2.5
Retained for backward compatibility only
Retained for backward compatibility only
3.4.5.33
3.4.5.34
3.4.2.10
3.4.5.36
3.4.5.37
3.4.5.38
3.4.3.16
3.4.3.1
3.4.3.2
3.4.3.3
3.4.3.4
3.4.3.5
3.4.3.6
3.4.3.7
Retained for backward compatibility only
Retained for backward compatibility only
3.4.3.8
Retained for backward compatibility only
Retained for backward compatibility only
3.4.3.9
Retained for backward compatibility only
Retained for backward compatibility only
3.4.3.10
3.4.3.11
3.4.3.12
3.4.3.13
3.4.3.14
3.4.3.15
3.4.3.16
3.4.3.17
Retained for backward compatibility only
Retained for backward compatibility only
3.4.3.18
3.4.3.19
3.4.3.20
Retained for backward compatibility only
3.4.3.21
3.4.3.22
3.4.3.23
3.4.3.24
3.4.3.25
3.4.3.26
3.4.3.27
3.4.3.28
3.4.3.29
3.4.3.30
3.4.3.31
3.4.3.32
3.4.3.33
3.4.3.34
3.4.3.35
3.4.3.36
3.4.3.37
Retained for backward compatibility only
3.4.3.38
3.4.3.39
3.4.3.40
3.4.3.41
3.4.3.42
3.4.3.43
3.4.3.44
Retained for backward compatibility only
3.4.3.45
Retained for backward compatibility only
3.4.3.46
3.4.3.47
3.4.3.48
3.4.3.49
3.4.3.50
3.4.3.51
3.4.3.52
Retained for backward compatibility only
Retained for backward compatibility only
3.4.4.1
3.4.4.2
3.4.4.3
3.4.4.4
3.4.4.5
3.4.4.6
3.4.4.7
3.4.4.8
Retained for backward compatibility only
3.4.4.9
Retained for backward compatibility only
3.4.4.10
3.4.4.11
3.4.4.12
3.4.4.13
Retained for backward compatibility only
Retained for backward compatibility only
3.4.4.14
3.4.4.15
3.4.4.16
3.4.4.17
3.4.4.18
3.4.4.19
3.4.4.20
3.4.4.21
3.4.4.22
3.4.4.23
3.4.4.24
3.4.4.25
3.4.4.26
3.4.4.27
3.4.4.28
3.4.4.29
3.4.4.30
3.4.4.31
3.4.4.32
3.4.4.33
Retained for backward compatibility only
3.4.4.34
3.4.4.35
3.4.4.36
3.4.4.37
3.4.4.38
3.4.4.39
3.4.4.40
3.4.4.41
3.4.4.42
3.4.4.43
3.4.4.44
3.4.4.45
3.4.4.46
3.4.4.47
Retained for backward compatibility only
3.4.4.48
Retained for backward compatibility only
3.4.4.49
6.5.6.1
6.5.1.14
6.5.6.3
6.5.6.4
6.5.6.5
deprecated as of v2.5
Retained for backward compatibility only
Retained for backward compatibility only
6.5.6.6
Retained for backward compatibility only
Retained for backward compatibility only
6.5.6.7
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.6.8
6.5.6.9
6.5.6.10
6.5.6.11
6.5.6.12
6.5.6.13
6.5.6.14
6.5.6.15
6.5.6.16
Retained for backward compatibility only
Retained for backward compatibility only
6.5.6.17
6.5.6.18
Retained for backward compatibility only
6.5.6.19
deprecated as of v2.5
Retained for backward compatibility only
Retained for backward compatibility only
6.5.6.20
6.5.6.21
6.5.6.22
6.5.6.23
6.5.6.24
6.5.6.25
6.5.6.26
6.5.6.27
6.5.6.28
6.5.6.29
Retained for backward compatibility only
6.5.6.30
Retained for backward compatibility only
Retained for backward compatibility only
6.5.6.31
6.5.6.32
6.5.6.33
6.5.6.34
6.5.6.35
6.5.6.36
6.5.6.37
Using ISO
6.5.6.38
Using ISO
6.5.6.39
6.5.6.40
Using ISO
6.5.6.41
Using ISO
6.5.6.42
6.5.6.43
6.5.6.44
deprecated as of v2.5
Retained for backward compatibility only
Retained for backward compatibility only
6.5.6.45
6.5.6.46
6.5.6.47
3.4.5.36
6.5.6.49
6.5.6.50
6.5.6.51
6.5.6.52
6.5.6.53
6.5.7.1
6.5.7.2
6.5.7.3
Retained for backward compatibility only
Retained for backward compatibility only
6.5.7.4
6.5.7.5
6.5.7.6
6.5.7.7
Retained for backward compatibility only
Retained for backward compatibility only
6.5.7.8
6.5.7.9
Retained for backward compatibility only
Retained for backward compatibility only
6.5.7.10
6.5.7.11
6.5.7.12
6.5.7.13
6.5.7.14
3.4.10.20
6.5.7.16
6.5.7.17
6.5.7.18
6.5.7.19
6.5.7.20
6.5.7.21
6.5.7.22
Retained for backward compatibility only
Retained for backward compatibility only
6.5.7.23
6.5.7.24
6.5.7.25
6.5.7.26
6.5.7.27
6.5.7.28
2.16.39
2.16.39
2.16.50
2.16.46
6.5.7.29
6.5.7.30
Using ISO
3.4.5.17
3.4.3.15
3.4.2.26
3.4.2.15
3.4.5.21
3.4.5.22
3.4.5.23
3.4.5.24
3.4.2.17
3.4.2.6
Retained for backward compatibility only
Retained for backward compatibility only
3.4.2.28
3.4.2.22
3.4.2.16
6.5.7.44
6.5.5.32
6.5.5.49
6.5.5.50
3.4.5.34
6.5.7.49
Retained for backward compatibility only
Retained for backward compatibility only
6.5.7.50
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.7.51
6.5.7.52
Retained for backward compatibility only
Retained for backward compatibility only
6.5.7.53
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.7.54
6.5.7.55
6.5.7.56
6.5.7.57
6.5.7.58
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.7.59
6.5.7.60
6.5.7.61
6.5.7.62
6.5.7.63
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.7.64
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.7.65
6.5.7.66
6.5.7.67
6.5.7.68
6.5.7.69
6.5.7.70
3.4.2.10
6.5.7.72
6.5.8.1
6.5.8.2
6.5.8.3
Retained for backward compatibility only
Retained for backward compatibility only
6.5.8.4
6.5.8.5
6.5.8.6
Retained for backward compatibility only
6.5.8.7
Retained for backward compatibility only
6.5.8.8
Retained for backward compatibility only
Retained for backward compatibility only
6.5.8.9
6.5.8.10
6.5.8.11
6.5.8.12
6.5.8.13
Retained for backward compatibility only
6.5.8.14
Retained for backward compatibility only
Retained for backward compatibility only
6.5.8.15
6.5.8.16
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.8.17
6.5.8.18
6.5.8.19
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.8.20
Retained for backward compatibility only
6.5.8.21
6.5.8.22
6.5.8.23
6.5.8.24
6.5.8.25
Retained for backward compatibility only
Retained for backward compatibility only
6.5.5.1
6.5.5.2
6.5.5.3
Retained for backward compatibility only
Retained for backward compatibility only
6.5.5.4
Retained for backward compatibility only
Retained for backward compatibility only
6.5.5.5
deprecated as of v2.5
Retained for backward compatibility only
Retained for backward compatibility only
6.5.5.6
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.5.7
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.5.8
Retained for backward compatibility only
6.5.5.9
6.5.5.10
6.5.5.11
6.5.5.12
6.5.5.13
6.5.5.14
6.5.5.15
6.5.5.16
Retained for backward compatibility only
Retained for backward compatibility only
6.5.5.17
deprecated as of v2.5
Retained for backward compatibility only
Retained for backward compatibility only
6.5.5.18
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
6.5.5.19
6.5.5.20
6.5.5.21
6.5.5.22
6.5.5.23
6.5.5.24
Retained for backward compatibility only
6.5.5.25
6.5.5.26
6.5.5.27
Using ISO
6.5.5.28
6.5.5.29
6.5.5.30
6.5.5.31
6.5.5.32
3.4.5.17
3.4.3.15
3.4.2.26
3.4.2.15
3.4.5.21
3.4.5.22
3.4.5.23
3.4.5.24
3.4.2.17
3.4.2.6
Retained for backward compatibility only
Retained for backward compatibility only
3.4.2.28
3.4.2.22
3.4.5.30
Retained for backward compatibility only
Retained for backward compatibility only
3.4.5.31
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
3.4.5.29
6.5.5.48
6.5.5.49
6.5.5.50
6.5.5.51
3.4.5.36
3.4.5.34
6.5.5.54
Retained for backward compatibility only
6.5.5.55
6.5.5.56
3.4.3.16
3.4.6.1
3.4.6.2
3.4.6.3
3.4.6.4
3.4.6.5
3.4.6.6
7.4.3.1
This field must be populated in OML messages of transaction T1, in the
context of the use case "Externally placed order with identified specimens"
defined in volume 1. This field is required in OML messages of the T2
transactions. It may also be used in transactions T3, T4 and T5
7.4.3.2
This version of the IHE of Laboratory Technical Framework doesn't admit
pooling of specimens, therefore the maximum cardinality for the parent
specimen is 1. See the data model in volume 1 of this document.
7.4.3.3
7.4.3.4
NULL or from HL70487 or vendor-defined
7.4.3.5
7.4.3.6
7.4.3.7
7.4.3.8
7.4.3.9
7.4.3.10
7.4.3.11
7.4.3.12
2.16.50
7.4.3.13
7.4.3.14
7.4.3.15
This field must be populated if known in OML messages sent by the Order
Placer, within transaction T1, and OML messages sent by the Order Filler
within transactions T2 and T4
7.4.3.16
The date and time when the specimen was acquired from the source. The
use of the Date Range data type allows for description of specimens
collected over a period of time, for example, 24-hour urine collection. For
specimens collected at a point in time, only the first component (start
date/time) will be populated
7.4.3.17
Retained for backward compatibility only
Retained for backward compatibility only
4.5.3.14
Retained for backward compatibility only
7.4.3.19
Retained for backward compatibility only
This field is pointless in messages sent by the Order Placer.
7.4.3.20
7.4.3.21
7.4.3.22
7.4.3.23
7.4.3.24
7.4.3.25
2.16.50
For sample receipt verification purposes; may be different from the
total number of specimens that accompany the order.
7.4.3.26
7.4.3.27
7.4.3.28
7.4.3.29
Pre-adopted from HL7 2.9
2.15.10.1
For comment generated at the Analyzer Manager, NTE-2 shall be populated with "A" (for Analyzer Manager)
2.15.10.2
This field contains the text of the comment. This text may be
formatted. In order to delete an existing comment, the field shall
contain empty quotation marks: " " . Comment text of identical type
and source shall be included in the same occurrence of an NTE
segment, and not be split over multiple segments.
2.15.10.3
The IHE Laboratory Technical Framework populates this field
with one of the values in table IHE0364
2.15.10.4
Since the OBX-18 field should not be used; this OBX-19 field is pointless.
This field contains the sequence number of the OBX.
7.4.2.1
7.4.2.2
The usage of LOINC(r) test codes for the identification of tests is strongly
recommended. Details of this free vocabulary can be found at http://www.loinc.org
7.4.2.3
7.4.2.4
7.4.2.5
7.4.2.6
7.4.2.7
The predicate for OBX-8-3 is that OBX-8-1 is not NULL
7.4.2.8
7.4.2.9
7.4.2.10
7.4.2.11
Since the Reference range given by the order filler is the one that applies to
the Observation result taking into account some other parameters like patient age or
sex; there is not need to manage the present field. The Order Result Tracker should
store the observation result and its associated reference range. In case the Order
Result Tracker offers the capability to compare results of the same observation over
different requests, it should then associate each result with its associated reference
range.
7.4.2.12
Retained for backward compatibility only
7.4.2.13
Required if available This field should be valued when the OBX-5 field (Value
field) is also valued. In very exceptional case this information may be unknown by the
Order Filler (case the test is transmitted in a reference lab and observation date and
time is not returned together with the result), this field can be null and the Order
Result Tracker should not generate an error.
7.4.2.14
Retained for backward compatibility only
Required if available This field is required in case the observation was not
produced by the sending organization
7.4.2.15
This field is required when the observation result status (OBX-11) is valued with
"D" or "R" or "P" or "F" or "C" or "X" and the Producer's ID field is not valued. It
should contain the identity of the observer that causes the change of the observation
result status. Only the first component (ID number) of this field is necessary, provided
that it is possible to retrieve the full identity of responsible person in the Order
Filler system with this only ID number.
7.4.2.16
Retained for backward compatibility only
Retained for backward compatibility only
7.4.2.17
7.4.2.18
7.4.2.19
Retained for backward compatibility only
7.4.2.20
7.16.4.21
7.4.2.22
7.16.6.23
9.6.2.24
7.16.3.25
7.4.2.27 (HL7V2.8)
7.4.2.27 (HL7V2.8)
The field was pre-adopted from HL7 v2.8.1
13.4.3.1
4.5.6.1
13.4.3.3
13.4.3.4
13.4.3.5
4.5.3.15
13.4.3.7
Retained for backward compatibility only
13.4.3.8
13.4.3.9
13.4.3.10
13.4.3.11
13.4.3.12
13.4.3.13
13.4.3.14
13.4.3.15
13.4.3.16
13.4.3.17
13.4.3.18
13.4.3.19
13.4.3.20
8.8.11.4
13.4.3.22
13.4.3.23
13.4.3.24
13.4.3.25
13.4.3.26
8.8.11.7
13.4.3.28
13.4.3.29
13.4.3.30
13.4.3.31
13.4.3.32
13.4.3.33
13.4.3.34
13.4.3.35
13.4.3.36
13.4.3.37
13.4.3.38
13.4.3.39
13.4.3.40
13.4.3.41
13.4.3.42
13.4.3.43
13.4.3.44
Pre-adopted from HL7 2.9
2.15.10.1
For comment generated at the Analyzer Manager, NTE-2 shall be populated with "A" (for Analyzer Manager)
2.15.10.2
This field contains the text of the comment. This text may be
formatted. In order to delete an existing comment, the field shall
contain empty quotation marks: " " . Comment text of identical type
and source shall be included in the same occurrence of an NTE
segment, and not be split over multiple segments.
2.15.10.3
The IHE Laboratory Technical Framework populates this field
with one of the values in table IHE0364
2.15.10.4
This conformance profile addresses the case where ORC-1 = DC
This field may be considered the "trigger event" identifier for orders. Many
order control codes are defined in the HL7 table 0119 - Order Control Codes. The IHE
Laboratory Technical Framework allows only a subset of it
4.5.1.1
4.5.1.2
4.5.1.3
required if known to the sender. The Placer Group Number represents an
identification of a set of closely related orders, i.e. the whole list of batteries
ordered by the placer to the laboratory for one subject.
4.5.1.4
4.5.1.5
4.5.1.6
4.5.1.7
2.16.50
2.16.67
2.16.78
2.16.82
Retained for backward compatibility only
2.16.82
Retained for backward compatibility only
2.16.78
2.16.78
2.16.83
2.16.38
2.16.50
4.5.1.8
This field contains the date and time of the event that initiated the current
transaction as reflected in ORC-1 Order Control Code. This field is not equivalent to
MSH-7 Date and Time of Message that reflects the date/time of the creation of the
physical message. In OML messages "Status changed" sent by the Order Filler, this
field contains the date/time of the last status change of the order (ORC-5) or one of
the ordered batteries (identified in the following OBR).
4.5.1.9
Retained for backward compatibility only
4.5.1.10
Retained for backward compatibility only
Retained for backward compatibility only
4.5.1.11
Retained for backward compatibility only
Retained for backward compatibility only
This field contains the person (physician) who prescribed the order. See the
data model in volume 1.
4.5.1.12
Retained for backward compatibility only
Retained for backward compatibility only
4.5.1.13
If the field is valued then its value has to match the value of the required
field OBR-17.
4.5.1.14
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
4.5.1.15
Retained for backward compatibility only
4.5.1.16
4.5.1.17
4.5.1.18
4.5.1.19
Retained for backward compatibility only
Retained for backward compatibility only
4.5.1.20
This field contains the facility (care unit) placing this order. See the data
model in volume 1.
4.5.1.21
4.5.1.22
deprecated as of v2.5
Retained for backward compatibility only
Retained for backward compatibility only
4.5.1.23
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
4.5.1.24
deprecated as of v2.5
Retained for backward compatibility only
Retained for backward compatibility only
4.5.1.25
4.5.1.26
This field contains the date/time when the laboratory results are expected to
be available.
4.5.1.27
Retained for backward compatibility only
4.5.1.28
4.5.1.29
4.5.1.30
Pre-adopted from HL7 2.9
2.15.10.1
For comment generated at the Analyzer Manager, NTE-2 shall be populated with "A" (for Analyzer Manager)
2.15.10.2
This field contains the text of the comment. This text may be
formatted. In order to delete an existing comment, the field shall
contain empty quotation marks: " " . Comment text of identical type
and source shall be included in the same occurrence of an NTE
segment, and not be split over multiple segments.
2.15.10.3
The IHE Laboratory Technical Framework populates this field
with one of the values in table IHE0364
2.15.10.4
This cycle of IHE Laboratory Technical Framework uses doesn't use
TQ2 segment, and uses only one occurrence of TQ1 segment, with a single
field required in it : TQ1-9 Priority (CWE).
4.5.4.1
4.5.4.2
2.16.50
4.5.4.3
2.16.16
2.16.38
2.16.50
2.16.50
2.16.50
Constrained to units of time. The codes for unit of measure
are specified in the Unified Code for Units of Measure (UCUM)
[http://aurora.rg.iupui.edu/UCUM].
2.16.39
2.16.38
2.16.38
2.16.50
Constrained to units of time. The codes for unit of measure
are specified in the Unified Code for Units of Measure (UCUM)
[http://aurora.rg.iupui.edu/UCUM].
4.5.4.4
4.5.4.5
2.16.50
4.5.4.6
2.16.50
4.5.4.7
Retained for backward compatibility only
4.5.4.8
Retained for backward compatibility only
4.5.4.9
4.5.4.10
4.5.4.11
4.5.4.12
4.5.4.13
2.16.50
4.5.4.14
4.5.5.1
4.5.5.2
4.5.5.3
4.5.5.4
4.5.5.5
4.5.5.6
4.5.5.7
4.5.5.8
2.16.50
4.5.5.9
4.5.5.10
4.5.3.1
4.5.1.2
AWOS ID
4.5.1.3
4.5.3.4
4.5.3.5
4.5.3.6
Retained for backward compatibility only
4.5.3.7
Retained for backward compatibility only
4.5.3.8
Retained for backward compatibility only
4.5.3.9
2.16.50
4.5.3.10
Retained for backward compatibility only
Retained for backward compatibility only
4.5.3.11
4.5.3.12
4.5.3.13
4.5.3.14
Retained for backward compatibility only
4.5.3.15
4.5.1.12
Retained for backward compatibility only
Retained for backward compatibility only
4.5.3.17
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C any text]
4.5.3.18
4.5.3.19
4.5.3.20
4.5.3.21
4.5.3.22
Retained for backward compatibility only
4.5.3.23
Using ISO
4.5.3.24
4.5.3.25
4.5.3.26
4.5.1.7
2.16.50
2.16.67
2.16.78
2.16.82
Retained for backward compatibility only
2.16.82
Retained for backward compatibility only
2.16.78
2.16.78
2.16.83
2.16.38
2.16.50
4.5.3.28
Retained for backward compatibility only
Retained for backward compatibility only
4.5.3.29
4.5.3.30
4.5.3.31
4.5.3.32
Retained for backward compatibility only
Retained for backward compatibility only
4.5.3.33
Retained for backward compatibility only
Retained for backward compatibility only
4.5.3.34
Retained for backward compatibility only
Retained for backward compatibility only
4.5.3.35
Retained for backward compatibility only
Retained for backward compatibility only
4.5.3.36
Retained for backward compatibility only
4.5.3.37
4.5.3.38
4.5.3.39
4.5.3.40
4.5.3.41
4.5.3.42
4.5.3.43
4.5.3.44
4.5.3.45
4.5.3.46
4.5.3.47
4.5.3.48
4.5.3.49
4.5.3.4
13.4.10.2
13.4.10.3
13.4.10.4
13.4.9.7
13.4.9.10
13.4.10.7
13.4.10.8
2.15.10.1
2.15.10.2
This field contains the text of the comment. This text may be
formatted. In order to delete an existing comment, the field shall
contain empty quotation marks: " " . Comment text of identical type
and source shall be included in the same occurrence of an NTE
segment, and not be split over multiple segments.
2.15.10.3
The IHE Laboratory Technical Framework populates this field
with one of the values in table IHE0364
2.15.10.4
6.5.2.1
6.5.2.2
6.5.2.3
6.5.2.4
6.5.2.5
Retained for backward compatibility only
6.5.2.6
6.5.2.7
6.5.2.8
6.5.2.9
6.5.2.10
6.5.2.11
6.5.2.12
6.5.2.13
Using ISO
6.5.2.14
6.5.2.15
6.5.2.16
Retained for backward compatibility only
Retained for backward compatibility only
6.5.2.17
6.5.2.18
6.5.2.19
Retained for backward compatibility only
6.5.2.20
6.5.2.21
Since the OBX-18 field should not be used; this OBX-19 field is pointless.
This field contains the sequence number of the OBX.
7.4.2.1
7.4.2.2
The usage of LOINC(r) test codes for the identification of tests is strongly
recommended. Details of this free vocabulary can be found at http://www.loinc.org
7.4.2.3
7.4.2.4
7.4.2.5
7.4.2.6
required if available. This field should be valued as described in HL7 V2.5
for all observations for which it is relevant. The References range that figures in
this field is supposed to be related to age and sex of the patient or to other
parameters such as number of weeks of pregnancy when applicable, which makes the
OBX-10 field (nature of abnormal test) unnecessary.
7.4.2.7
required if available. This field is required when applicable. Among the
possible values listed for this field in HL7 table 0078, the actors of IHE
Laboratory Technical Framework should support the values of table 0078 As described
in the above table, the S, R, or I values must be used to indicate the interpreted
result of susceptibilities in microbiology, in case the value field (OBX-5) contains
a numeric value that represents the MIC (Minimum Inhibitive Concentration). In case
the order filler only reports the interpreted result for susceptibilities, the S, R,
or I value could be filled in the value field (OBX-5) with a Value Type (OBX-2) set
to "ST".
7.4.2.8
7.4.2.9
7.4.2.10
This field should be filled according to HL7 Table 0085 described in Chapter
7 of HL7. In this version of the Laboratory Technical Version, the possible values
for this field are a subset of this table:
7.4.2.11
Since the Reference range given by the order filler is the one that applies
to the Observation result taking into account some other parameters like patient age
or sex; there is not need to manage the present field. The Order Result Tracker
should store the observation result and its associated reference range. In case the
Order Result Tracker offers the capability to compare results of the same
observation over different requests, it should then associate each result with its
associated reference range.
7.4.2.12
Retained for backward compatibility only
7.4.2.13
Required if available This field should be valued when the OBX-5 field (Value
field) is also valued. In very exceptional case this information may be unknown by
the Order Filler (case the test is transmitted in a reference lab and observation
date and time is not returned together with the result), this field can be null and
the Order Result Tracker should not generate an error.
7.4.2.14
Retained for backward compatibility only
Required if available This field is required in case the observation was not
produced by the sending organization
7.4.2.15
7.4.2.16
If the value is unknown, then a NULL value will beused for the ID number
Retained for backward compatibility only
Retained for backward compatibility only
7.4.2.17
Although this information should be available at the Order Filler
level, this field should not be used in this first version of the Laboratory
Technical Framework
7.4.2.18
Since the OBX-18 field should not be used; this OBX-19 field is pointless.
7.4.2.19
Retained for backward compatibility only
7.4.2.20
7.16.4.21
7.4.2.22
7.16.6.23
9.6.2.24
7.16.3.25
7.4.2.27 (HL7V2.8)
7.4.2.27 (HL7V2.8)
The field was pre-adopted from HL7 v2.8.1
4.5.3.4
Test/battery identifier
Name for the test/battery
LN, JC10 or 99zzz
13.4.10.2
13.4.10.3
13.4.10.4
13.4.9.7
13.4.9.10
13.4.10.7
13.4.10.8
from W.3.12-9
2.15.10.1
2.15.10.2
This field contains the text of the comment. This text may
be formatted. In order to delete an existing comment, the field
shall contain empty quotation marks: " " . Comment text of
identical type and source shall be included in the same
occurrence of an NTE segment, and not be split over multiple
segments.
2.15.10.3
The IHE Laboratory Technical Framework populates this field
with one of the values in table IHE0364
2.15.10.4
The specific usage of the fields,withusage " Optional" in
the tablePID, is explained in the nationalextensions.
3.4.2.1
3.4.2.2
*
3.4.2.3
3.4.2.4
3.4.2.5
Retained for backward compatibility
only
Retained for backward compatibility
only
3.4.2.6
Retained for backward compatibility
only
Retained for backward compatibility
only
If the exact date of birth is not known, thesecond
component of this field can beused to describe the degree of
precisionof the information entered in the firstcomponent.
3.4.2.7
Retained for backward compatibility only
3.4.2.8
3.4.2.9
Retained for backward compatibility
only
Retained for backward compatibility
only
3.4.2.10
3.4.2.11
deprecated as of v2.5
Retained for backward compatibility
only
Retained for backward compatibility
only
3.4.2.12
3.4.2.13
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C
anytext]
3.4.2.14
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C
anytext]
3.4.2.15
3.4.2.16
3.4.2.17
the Patient Account Number is not used insome
countries: in the US, it must bevalued and the PV1-19 visit
number isrequired when PID-18 identifies anaccount that
spans more than oneEncounter or Visit. In France, PID-18
maybe used when a patient may havemultiplevisits (each visit
having independenttransfer and discharge) but where all
thevisit need to be linked under onecase/episode number.
3.4.2.18
3.4.2.19
3.4.2.20
3.4.2.21
3.4.2.22
3.4.2.23
3.4.2.24
3.4.2.25
3.4.2.26
3.4.2.27
3.4.2.28
3.4.2.29
Retained for backward compatibility only
3.4.2.30
3.4.2.31
3.4.2.32
3.4.2.33
Retained for backward compatibility only
3.4.2.35
3.4.2.36
3.4.2.37
3.4.2.38
3.4.2.39
3.4.5.17
3.4.5.21
3.4.10.3
3.4.10.4
Retained for backward compatibility
only
Retained for backward compatibility
only
3.4.5.24
3.4.5.36
3.4.4.43
3.4.4.44
3.4.10.9
3.4.10.10
3.4.5.22
3.4.5.23
3.4.10.13
3.4.10.14
3.4.10.15
3.4.10.16
3.4.10.17
3.4.10.18
3.4.10.19
3.4.10.20
3.4.10.21
3.4.3.1
3.4.3.2
3.4.3.3
3.4.3.4
3.4.3.5
3.4.3.6
3.4.3.7
Retained for backward compatibility
only
Retained for backward compatibility
only
3.4.3.8
Retained for backward compatibility
only
Retained for backward compatibility
only
3.4.3.9
Retained for backward compatibility
only
Retained for backward compatibility
only
3.4.3.10
3.4.3.11
3.4.3.12
3.4.3.13
3.4.3.14
3.4.3.15
3.4.3.16
3.4.3.17
Retained for backward compatibility
only
Retained for backward compatibility
only
3.4.3.18
3.4.3.19
3.4.3.20
Retained for backward compatibility
only
3.4.3.21
3.4.3.22
3.4.3.23
3.4.3.24
3.4.3.25
3.4.3.26
3.4.3.27
3.4.3.28
3.4.3.29
3.4.3.30
3.4.3.31
3.4.3.32
3.4.3.33
3.4.3.34
3.4.3.35
3.4.3.36
3.4.3.37
Retained for backward compatibility
only
3.4.3.38
3.4.3.39
3.4.3.40
3.4.3.41
3.4.3.42
3.4.3.43
3.4.3.44
Retained for backward compatibility only
3.4.3.45
Retained for backward compatibility only
3.4.3.46
3.4.3.47
3.4.3.48
3.4.3.49
3.4.3.50
3.4.3.51
3.4.3.52
Retained for backward compatibility
only
Retained for backward compatibility
only
3.4.4.1
3.4.4.2
3.4.4.3
3.4.4.4
3.4.4.5
3.4.4.6
3.4.4.7
3.4.4.8
Retained for backward compatibility only
3.4.4.9
Retained for backward compatibility only
3.4.4.10
3.4.4.11
3.4.4.12
3.4.4.13
Retained for backward compatibility
only
Retained for backward compatibility
only
3.4.4.14
3.4.4.15
3.4.4.16
3.4.4.17
3.4.4.18
3.4.4.19
3.4.4.20
3.4.4.21
3.4.4.22
3.4.4.23
3.4.4.24
3.4.4.25
3.4.4.26
3.4.4.27
3.4.4.28
3.4.4.29
3.4.4.30
3.4.4.31
3.4.4.32
3.4.4.33
Retained for backward compatibility only
3.4.4.34
3.4.4.35
3.4.4.36
3.4.4.37
3.4.4.38
3.4.4.39
3.4.4.40
3.4.4.41
3.4.4.42
3.4.4.43
3.4.4.44
3.4.4.45
3.4.4.46
3.4.4.47
Retained for backward compatibility only
3.4.4.48
Retained for backward compatibility only
3.4.4.49
3.4.6.1
3.4.6.2
3.4.6.3
3.4.6.4
3.4.6.5
3.4.6.6
This field may be considered the "triggerevent" identifier
for orders. Many ordercontrol codes are defined in the HL7
table0119 - Order Control Codes. The IHELaboratory Technical
Framework allowsonly a subset of it
This field may be considered the "triggerevent"
identifier for orders. Many ordercontrol codes are defined
in the HL7 table0119 - Order Control Codes. The
IHELaboratory Technical Framework allowsonly a subset of it
4.5.1.1
4.5.1.2
4.5.1.3
required if known to the sender. ThePlacer Group Number
represents anidentification of a set of closely
relatedorders, i.e. the whole list of batteriesordered by
the placer to the laboratoryfor one subject.
4.5.1.4
4.5.1.5
4.5.1.6
4.5.1.7
2.16.50
2.16.67
2.16.78
2.16.82
Retained for backward compatibility
only
2.16.82
Retained for backward compatibility
only
2.16.78
2.16.78
2.16.83
2.16.38
2.16.50
4.5.1.8
This field contains the date and time ofthe event that
initiated the currenttransaction as reflected in ORC-1
OrderControl Code. This field is not equivalentto MSH-7 Date
and Time of Message thatreflects the date/time of the
creation ofthe physical message.In OML messages "Status
changed" sentby the Order Filler, this field contains
thedate/time of the last status change of theorder (ORC-5)
or one of the orderedbatteries (identified in the following
OBR).
4.5.1.9
Retained for backward compatibility only
4.5.1.10
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.1.11
Retained for backward compatibility
only
Retained for backward compatibility
only
This field contains the person (physician)who
prescribed the order. See the datamodel in volume 1.
4.5.1.12
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.1.13
If the field is valued then its value has tomatch the
value of the required fieldOBR-17.
4.5.1.14
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C
anytext]
4.5.1.15
Retained for backward compatibility only
4.5.1.16
4.5.1.17
4.5.1.18
4.5.1.19
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.1.20
This field contains the facility (care unit)placing
this order. See the data model involume 1.
4.5.1.21
4.5.1.22
deprecated as of v2.5
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.1.23
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C
anytext]
4.5.1.24
deprecated as of v2.5
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.1.25
4.5.1.26
This field contains the date/time when thelaboratory
results are expected to beavailable.
4.5.1.27
Retained for backward compatibility only
4.5.1.28
4.5.1.29
4.5.1.30
These segement differ for the T1 and theT2 transactions.
Thus this is only herethedefault from 2.5 non modified, just to
bethere when we need it.
4.5.3.1
4.5.1.2
4.5.1.3
4.5.3.4
4.5.3.5
4.5.3.6
Retained for backward compatibility only
4.5.3.7
Retained for backward compatibility only
4.5.3.8
Retained for backward compatibility only
4.5.3.9
2.16.50
4.5.3.10
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.3.11
4.5.3.12
4.5.3.13
4.5.3.14
Retained for backward compatibility only
4.5.3.15
4.5.1.12
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.3.17
Format: [NNN] [(999)]999-9999 [X99999] [B99999] [C
anytext]
4.5.3.18
4.5.3.19
4.5.3.20
4.5.3.21
4.5.3.22
Retained for backward compatibility only
4.5.3.23
Using ISO
4.5.3.24
4.5.3.25
4.5.3.26
4.5.1.7
2.16.50
2.16.67
2.16.78
2.16.82
Retained for backward compatibility
only
2.16.82
Retained for backward compatibility
only
2.16.78
2.16.78
2.16.83
2.16.38
2.16.50
4.5.3.28
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.3.29
4.5.3.30
4.5.3.31
4.5.3.32
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.3.33
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.3.34
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.3.35
Retained for backward compatibility
only
Retained for backward compatibility
only
4.5.3.36
Retained for backward compatibility only
4.5.3.37
4.5.3.38
4.5.3.39
4.5.3.40
4.5.3.41
4.5.3.42
4.5.3.43
4.5.3.44
4.5.3.45
4.5.3.46
4.5.3.47
4.5.3.48
4.5.3.49
2.15.10.1
2.15.10.2
This field contains the text of thecomment. This text
may be formatted. Inorder to delete an existing comment,
thefield shall contain empty quotation marks:"" .Comment
text of identical type andsourceshall be included in the
same occurrenceof an NTE segment, and not be split
overmultiple segments.
2.15.10.3
The IHE Laboratory Technical Frameworkpopulates this
field with one of the valuesin table IHE0364
2.15.10.4
This cycle of IHE Laboratory TechnicalFramework uses
doesn't use TQ2segment, and uses only one occurrenceof TQ1
segment, with a single fieldrequired in it : TQ1-9 Priority
(CWE).
4.5.4.1
4.5.4.2
2.16.50
4.5.4.3
2.16.16
2.16.38
2.16.50
2.16.50
2.16.50
Constrained to units of time. The codes for
unit ofmeasure are specified in the Unified Code for
Units ofMeasure (UCUM)
[http://aurora.rg.iupui.edu/UCUM].
2.16.39
2.16.38
2.16.38
2.16.50
Constrained to units of time. The codes for
unit ofmeasure are specified in the Unified Code for
Units ofMeasure (UCUM)
[http://aurora.rg.iupui.edu/UCUM].
4.5.4.4
4.5.4.5
2.16.50
4.5.4.6
2.16.50
4.5.4.7
Retained for backward compatibility
only
4.5.4.8
Retained for backward compatibility
only
Transactions T1, T2 and T3 restrict theusage to the
6 values: S, A, R, P, C, T oftable 0485
4.5.4.9
4.5.4.10
4.5.4.11
4.5.4.12
4.5.4.13
2.16.50
4.5.4.14
4.5.5.1
4.5.5.2
4.5.5.3
4.5.5.4
4.5.5.5
4.5.5.6
4.5.5.7
4.5.5.8
2.16.50
4.5.5.9
4.5.5.10
Since the OBX-18 field should not beused; this OBX-19
field is pointless.
This field contains the sequence numberof the OBX.
7.4.2.1
7.4.2.2
The usage of LOINC(r) test codes for
theidentification of tests is stronglyrecommended.
Details of this freevocabulary can be found
athttp://www.loinc.org
7.4.2.3
7.4.2.4
7.4.2.5
7.4.2.6
required if available. This field should bevalued
as described in HL7 V2.5 for allobservations for which
it is relevant. TheReferences range that figures in this
fieldis supposed to be related to age and sexof the
patient or to other parameters suchas number of weeks of
pregnancy whenapplicable, which makes the OBX-10
field(nature of abnormal test) unnecessary.
7.4.2.7
required if available.This field is required when
applicable.Among the possible values listed for
thisfield in HL7 table 0078, the actors of IHELaboratory
Technical Framework shouldsupport the values of table
0078As described in the above table, the S, R,or I
values must be used to indicate theinterpreted result of
susceptibilities inmicrobiology, in case the value
field(OBX-5) contains a numeric value thatrepresents the
MIC (Minimum InhibitiveConcentration). In case the order
filleronly reports the interpreted result
forsusceptibilities, the S, R, or I value couldbe filled
in the value field (OBX-5) with aValue Type (OBX-2) set
to "ST".
7.4.2.8
7.4.2.9
7.4.2.10
This field should be filled according toHL7 Table
0085 described in Chapter 7 ofHL7. In this version of
the LaboratoryTechnical Version, the possible valuesfor
this field are a subset of this table:
7.4.2.11
Since the Reference range given by theorder filler
is the one that applies to theObservation result taking
into accountsome other parameters like patient age
orsex; there is not need to manage thepresent field. The
Order Result Trackershould store the observation result
andits associated reference range. In casethe Order
Result Tracker offers thecapability to compare results
of the sameobservation over different requests, itshould
then associate each result with itsassociated reference
range.
7.4.2.12
Retained for backward compatibility
only
7.4.2.13
Required if availableThis field should be valued
when theOBX-5 field (Value field) is also valued. Invery
exceptional case this informationmay be unknown by the
Order Filler(case the test is transmitted in areference
lab and observation date andtime is not returned
together with theresult), this field can be null and
theOrderResult Tracker should not generate anerror.
7.4.2.14
Retained for backward compatibility
only
Required if available This field is requiredin case
the observation was notproduced by the sending
organization
7.4.2.15
This field is required when theobservation result
status (OBX-11) isvalued with "D" or "R" or "P" or "F"
or "C"or "X" and the Producer's ID field is notvalued.
It should contain the identity oftheobserver that causes
the change of theobservation result status. Only the
firstcomponent (ID number) of this field isnecessary,
provided that it is possible toretrieve the full
identity of responsibleperson in the Order Filler system
with thisonly ID number.
7.4.2.16
Retained for backward compatibility
only
Retained for backward compatibility
only
7.4.2.17
Although this information should beavailable at the
Order Filler level, this fieldshould not be used in this
first version ofthe Laboratory Technical Framework
7.4.2.18
Since the OBX-18 field should not beused; this
OBX-19 field is pointless.
7.4.2.19
Retained for backward compatibility
only
2.15.10.1
2.15.10.2
This field contains the text of thecomment. This
text may be formatted. Inorder to delete an existing
comment, thefield shall contain empty quotation marks:""
.Comment text of identical type andsourceshall be
included in the same occurrenceof an NTE segment, and
not be split overmultiple segments.
2.15.10.3
The IHE Laboratory Technical Frameworkpopulates
this field with one of the valuesin table IHE0364
2.15.10.4
6.5.1.1
6.5.1.2
6.5.1.3
6.5.1.4
Retained for backward compatibility only
Retained for backward compatibility only
6.5.1.5
Retained for backward compatibility only
6.5.1.6
6.5.1.7
6.5.1.8
6.5.1.9
6.5.1.10
6.5.1.11
Using ISO
6.5.1.12
Using ISO
6.5.1.13
6.5.1.14
6.5.1.15
Using ISO
3.4.3.3
6.5.1.17
3.4.3.18
6.5.1.19
6.5.1.20
Retained for backward compatibility only
Retained for backward compatibility only
6.5.1.21
Retained for backward compatibility only
Retained for backward compatibility only
6.5.1.22
Using ISO
4.5.1.3
6.5.1.24
Retained for backward compatibility only
Retained for backward compatibility only
4.5.3.44
4.5.3.45
4.5.1.20
4.5.3.48
6.5.1.29
6.5.1.30
6.5.1.31
7.8.1.1
7.8.2.1
7.8.3.1
4.5.2.1
Retained for backward compatibility only
4.5.2.2
4.5.2.3
4.5.2.4