IHE PCC - Supply Entry Checks wheter the CDA structure is conformant to the IHE PCC - Supply Entry IHE PCC - Supply Entry Verifies the structure of a IHE PCC - Supply Entry In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the moodCode attribute shall be INT to reflect that a medication has been prescribed, or EVN to indicate that the prescription has been filled. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the moodCode attribute shall be INT to reflect that a medication has been prescribed, or EVN to indicate that the prescription has been filled. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the parent CCD template ID (2.16.840.1.113883.10.20.1.34) shall be present. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the parent CCD template ID (2.16.840.1.113883.10.20.1.34) shall be present. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), each supply entry shall have an identifier to uniquely identify the supply entry. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), each supply entry shall have an identifier to uniquely identify the supply entry. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the value attribute of quantity shall be present if quantity exists. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the value attribute of quantity shall be present if quantity exists. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the <time> element must be present if author exists to indicate when the author created the prescription. If this information is unknown, it shall be recorded by setting the nullFlavor attribute to UNK. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the <time> element must be present if author exists to indicate when the author created the prescription. If this information is unknown, it shall be recorded by setting the nullFlavor attribute to UNK. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the <assignedAuthor> element shall be present if an author exists in Supply Entry, and identifies the author. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the <assignedAuthor> element shall be present if an author exists in Supply Entry, and identifies the author. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), an identifier element shall be present for an assigned author if an author exists in Supply Entry. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), an identifier element shall be present for an assigned author if an author exists in Supply Entry. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), an <assignedPerson>/<name> and/or <representedOriganization>/<name> element shall be present if an author exists in Supply Entry. This element shall identify the prescriber or their organization. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), an <assignedPerson>/<name> and/or <representedOriganization>/<name> element shall be present if an author exists in Supply Entry. This element shall identify the prescriber or their organization. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the <time> element shall be present if there is a performer in Supply Entry to indicate when the prescription was filled (moodCode='EVN'). If this information is unknown, it shall be recorded by setting the nullFlavor attribute to UNK. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the <time> element shall be present if there is a performer in Supply Entry to indicate when the prescription was filled (moodCode='EVN'). If this information is unknown, it shall be recorded by setting the nullFlavor attribute to UNK. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the <assignedEntity> element shall be present in a Supply Entry that contains a performer, and identifies the filler of the prescription. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), the <assignedEntity> element shall be present in a Supply Entry that contains a performer, and identifies the filler of the prescription. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), an assignedPerson/name and/or representedOriganization/name element shall be present under the assignedEntity if a performer exists. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), an assignedPerson/name and/or representedOriganization/name element shall be present under the assignedEntity if a performer exists. In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), an entry relationship may be present to provide the fulfillment instructions. When present, this entry relationship shall contain a Medication Fulfillment Instructions entry. Successfully tested: In IHE PCC Supply Entry (1.3.6.1.4.1.19376.1.5.3.1.4.7.3), an entry relationship may be present to provide the fulfillment instructions. When present, this entry relationship shall contain a Medication Fulfillment Instructions entry.