This test corresponds to Transaction ITI-45 of the IHE IT Infrastructure Technical Framework. Transaction ITI-45 is used by the Patient Identifier Cross-reference Consumer and Patient Identifier Cross-reference Manager actors.

Actor: PIX Consumer
Role: Queries the PIX Manager for a list of corresponding patient identifiers, if any.
Corresponding HL7 v3 Application Roles: Patient Registry Query Placer (PRPA_AR201303UV02)
Message Sent: Patient Registry Get Identifiers Query (PRPA_IN201309UV02)
Actor: PIX Manager
Role: Manages the cross-referencing of patient identifiers across Patient Identification Domains. Upon request it returns a list of corresponding patient identifiers, if any.
Corresponding HL7 v3 Application Roles: Patient Registry Query Fulfiller (PRPA_AR201304UV02)
Response Message: Patient Registry Get Identifiers Query Response (PRPA_IN201310UV02)

iti_9_interaction_diagram

In this test, the Orpheum Test bed will simulate the PIX Manager. The system under test will be the PIX Consumer. The Sending Facility and Application below are suggested. You may enter other values which your system will use if you wish. Orpheum uses the combination of these two values to identify individual tests on the PIX Manager simulator.
* Indicate whether you will test against the Open or Secure port.
* Set the Sending Facility and Application to what your client will send.
* Select "Start Test" to begin the testing operation.
* Select "Clear" to reset before starting test
* Send test message from your PIX Consumer.
* Select "Check for test results" to see what the PIX Manager simulator recorded.
* Select "End Test" to finish th testing operation.