IHE PCC - Vital Signs Organizer Checks wheter the CDA structure is conformant to the IHE PCC - Vital Signs Organizer IHE PCC - Vital Signs Organizer Verifies the structure of a IHE PCC - Vital Signs Organizer In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the Vital Signs Organizer shall have template IDs (2.16.840.1.113883.10.20.1.32 and 2.16.840.1.113883.10.20.1.35) to indicate that it inherits constraints from the ASTM/HL7 CCD Specification for Vital signs. Successfully tested: In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the Vital Signs Organizer shall have template IDs (2.16.840.1.113883.10.20.1.32 and 2.16.840.1.113883.10.20.1.35) to indicate that it inherits constraints from the ASTM/HL7 CCD Specification for Vital signs. In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the Vital Signs Organizer shall have an <id> element. Successfully tested: In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the Vital Signs Organizer shall have an <id> element. In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the <code> element of Vital Signs Organizer shall be recorded as shown to indicate that this organizer captures information about patient vital signs. <code code='46680005' displayName='Vital signs' codeSystem='2.16.840.1.113883.6.96' codeSystemName='SNOMED CT'/> Successfully tested: In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the <code> element of Vital Signs Organizer shall be recorded as shown to indicate that this organizer captures information about patient vital signs. <code code='46680005' displayName='Vital signs' codeSystem='2.16.840.1.113883.6.96' codeSystemName='SNOMED CT'/> In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the Vital Signs Organizer observations shall have all been completed. Successfully tested: In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the Vital Signs Organizer observations shall have all been completed. In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the effective time element shall be present in Vital Signs Organizer to indicate when the measurement was taken. Successfully tested: In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the effective time element shall be present in Vital Signs Organizer to indicate when the measurement was taken. In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the Vital Signs Organizer shall have one or more <component> elements that are <observation> elements using the Vital Signs Observation template (1.3.6.1.4.1.19376.1.5.3.1.4.13.2). Successfully tested: In IHE PCC Vital Signs Organizer (1.3.6.1.4.1.19376.1.5.3.1.4.13.1), the Vital Signs Organizer shall have one or more <component> elements that are <observation> elements using the Vital Signs Observation template (1.3.6.1.4.1.19376.1.5.3.1.4.13.2).