IHE PCC - Vital Signs Observation Checks wheter the CDA structure is conformant to the IHE PCC - Vital Signs Observation IHE PCC - Vital Signs Observation Verifies the structure of a IHE PCC - Vital Signs Observation In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), Vital Signs Observation shall include parent template IDs to indicate that it inherits constraints from the ASTM/HL7 CCD Specification for Vital signs (2.16.840.1.113883.10.20.1.31), and the constraints of this specification (1.3.6.1.4.1.19376.1.5.3.1.4.13). Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), Vital Signs Observation shall include parent template IDs to indicate that it inherits constraints from the ASTM/HL7 CCD Specification for Vital signs (2.16.840.1.113883.10.20.1.31), and the constraints of this specification (1.3.6.1.4.1.19376.1.5.3.1.4.13). In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a Vital Signs Observation shall use a LOINC code. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a Vital Signs Observation shall use a LOINC code. In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a Vital Signs Observation shall use a LOINC code from the table in the specification. See http://wiki.ihe.net/index.php?title=1.3.6.1.4.1.19376.1.5.3.1.4.13.2 Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a Vital Signs Observation shall use a LOINC code from the table in the specification. See http://wiki.ihe.net/index.php?title=1.3.6.1.4.1.19376.1.5.3.1.4.13.2 In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), the <value> element shall be present in Vital Signs Observation, and shall be of the appropriate data type specified for measure in the table. See http://wiki.ihe.net/index.php?title=1.3.6.1.4.1.19376.1.5.3.1.4.13.2 Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), the <value> element shall be present in Vital Signs Observation, and shall be of the appropriate data type specified for measure in the table. See http://wiki.ihe.net/index.php?title=1.3.6.1.4.1.19376.1.5.3.1.4.13.2 In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 9279-1 shall use units = '/min'. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 9279-1 shall use units = '/min'. In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8867-4 shall use units = '/min'. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8867-4 shall use units = '/min'. In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 2710-2 shall use units = '%'. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 2710-2 shall use units = '%'. In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8480-6 shall use units = 'mm[Hg]'. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8480-6 shall use units = 'mm[Hg]'. In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8462-4 shall use units = 'mm[Hg]'. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8462-4 shall use units = 'mm[Hg]'. In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8310-5 shall use units = 'Cel' or '[degF]'. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8310-5 shall use units = 'Cel' or '[degF]'. In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8302-2 shall use units = 'm' or 'cm' or '[in_us]' or '[in_uk]'. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8302-2 shall use units = 'm' or 'cm' or '[in_us]' or '[in_uk]'. In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8306-3 shall use units = 'm' or 'cm' or '[in_us]' or '[in_uk]'. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8306-3 shall use units = 'm' or 'cm' or '[in_us]' or '[in_uk]'. In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8287-5 shall use units = 'm' or 'cm' or '[in_us]' or '[in_uk]'. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 8287-5 shall use units = 'm' or 'cm' or '[in_us]' or '[in_uk]'. In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 3141-9 shall use units = 'kg' or 'g' or '[lb_av]' or '[oz_av]'. Successfully tested: In IHE PCC Vital Signs Observation (1.3.6.1.4.1.19376.1.5.3.1.4.13.2), a code of 3141-9 shall use units = 'kg' or 'g' or '[lb_av]' or '[oz_av]'.