IHE PCC - Concern Entry Checks wheter the CDA structure is conformant to the IHE PCC - Concern Entry IHE PCC - Concern Entry Verifies the structure of a IHE PCC - Concern Entry In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the Concern Entry can only be used on acts. Successfully tested: In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the Concern Entry can only be used on acts. In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), all concerns reflect the act of recording (<act classCode='ACT'>) the event (moodCode='EVN') of being concerned about a problem, allergy or other issue about the patient condition. Successfully tested: In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), all concerns reflect the act of recording (<act classCode='ACT'>) the event (moodCode='EVN') of being concerned about a problem, allergy or other issue about the patient condition. In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the required template identifiers indicates this Concern Entry conforms to the Concern Content module. This content module inherits constraints from the HL7 CCD Template for problem acts, and so also includes that template identifier (2.16.840.1.113883.10.20.1.27). Successfully tested: In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the required template identifiers indicates this Concern Entry conforms to the Concern Content module. This content module inherits constraints from the HL7 CCD Template for problem acts, and so also includes that template identifier (2.16.840.1.113883.10.20.1.27). In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the Concern Entry requires id element. Successfully tested: In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the Concern Entry requires id element. In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the code is not applicable to a concern act (Concern Entry), and so shall be recorded as <code nullFlavor='NA'/>. Successfully tested: In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the code is not applicable to a concern act (Concern Entry), and so shall be recorded as <code nullFlavor='NA'/>. In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the statusCode associated with any concern must be one of the following values: active, suspended, aborted or completed. Successfully tested: In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the statusCode associated with any concern must be one of the following values: active, suspended, aborted or completed. In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the <effectiveTime> element records the starting and ending times during which the concern (Concern Entry) was active. The <low> element shall be present. Successfully tested: In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the <effectiveTime> element records the starting and ending times during which the concern (Concern Entry) was active. The <low> element shall be present. In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the <effectiveTime> element records the starting and ending times during the concern (Concern Entry). The <high> element shall be present for concerns in the completed or aborted state, and shall not be present otherwise. Successfully tested: In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), the <effectiveTime> element records the starting and ending times during the concern (Concern Entry). The <high> element shall be present for concerns in the completed or aborted state, and shall not be present otherwise. In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), each concern (Concern Entry) is about one or more related problems or allergies. This entry shall contain one or more problem or allergy entries that conform to the specification in section Problem Entry or Allergies and Intolerances. This is how a series of related observations can be grouped as a single concern. For CDA this SHALL be represented with the <entryRelationship> element. For HL7 Version 3 Messages, this SHALL be represented as a <sourceOf> element. The typeCode SHALL be SUBJ for both HL7 Version 3 and CDA. HL7 Version 3 additionally requires that inversionInd SHALL be false. Successfully tested: In IHE PCC Concern Entry (1.3.6.1.4.1.19376.1.5.3.1.4.5.1), each concern (Concern Entry) is about one or more related problems or allergies. This entry shall contain one or more problem or allergy entries that conform to the specification in section Problem Entry or Allergies and Intolerances. This is how a series of related observations can be grouped as a single concern. For CDA this SHALL be represented with the <entryRelationship> element. For HL7 Version 3 Messages, this SHALL be represented as a <sourceOf> element. The typeCode SHALL be SUBJ for both HL7 Version 3 and CDA. HL7 Version 3 additionally requires that inversionInd SHALL be false.